Dr Zhuk of Hardide Coatings commented: “Water droplet erosion and fatigue are industry-wide pressing issues and we are very pleased with these initial test results which demonstrate the protection that the Hardide CVD coating offers against water droplet and solid particle erosion. Water droplet erosion damages the surface of steam and gas turbine blades, increasing turbine rotation drag and reducing efficiency. These tests have proven that the Hardide coating can protect the leading and trailing edges of the blades which will increase their service life and maintain optimal turbine efficiency for longer, saving downtime and maintenance costs.”
Dr Hahn of EDF Energy said: “These preliminary tests are very encouraging and show the Hardide CVD coating offers a significant improvement for preventing material loss rates.”
Hardide Plc (LON:HDD), the provider of advanced surface coating technology, has today announced that preliminary tests indicate that Hardide nanostructured chemical vapour deposition (CVD) coating can extend the life of steam turbine blades through significantly enhanced resistance to water droplet erosion (WDE) and solid particle erosion.
The tests, carried out by the National Physical Laboratory (“NPL”) and the University of Manchester (“UoM”), assessed the effectiveness of the Hardide coating as protection from WDE and cracking on FV520B last stage turbine blades.
After 90 hours of exposure to WDE (up to 1.2×108 water droplet impacts) Hardide-A coated 410 stainless steel samples showed almost no discernible damage in the central zone. The uncoated 410 stainless steel samples suffered major damage with a 200 microns deep scar across the sample face after a much shorter exposure of just 7 hours.
Tests commissioned by Hardide Coatings’ customer EDF Energy at the University of Manchester examined the static behaviour solid particle erosion resistance of the Hardide coating on FV520B steam turbine blade material. These yielded 0.18% weight loss for uncoated material compared to 0.04% weight loss for coated blades after 30 hours of static testing. The coating was shown to have a minimal effect on the blade’s natural frequencies; however, this effect is dependent on the coating thickness and blade design.
The results will be revealed today at the Institution of Mechanical Engineers’ STUG (Steam Turbine Users Group) conference in Manchester in a joint presentation by Dr Wolfgang Hahn, Commissioning Manager, Hinkley Point C (HPC) Nuclear New Build at EDF Energy, Hardide Coatings’ Technical Director, Dr Yuri Zhuk and Business Development Manager, Robin Gillham.
EDF Energy plans to begin field testing Hardide-coated blades in the near future.